Railway car air-conditioning device 35kW type
UKW.KB.01-35000SGW/3x400V~
Purpose
Air-conditioning device is designed for maintaining constant required temperature in new and modernized passenger cars as a result of air cooling or heating in inner circulation.
Air-conditioning device also secures car ventilation and air clearing from neutral contaminants (in form of dust, etc.).
General structure
Air-conditioning device is composed of two basic units: condenser and evaporator with electric reheater, fitted under the car in its middle part. Electrical protection is fitted within condenser unit. Whole air-conditioning device is controlled from inside of the car with MEDCOM control device.
Casing of the units is made of aluminium profiles and aluminium sheet metal. Condenser and evaporator’s cores are made of copper.
At customer’s request air-conditioning device may be fitted with internal-combustion reheater with 35 kW power liquid heating system.
Technical parameters
General parameters: |
Name | Railway car air-conditioning device |
Type | UKW.KB.01-35000SGW/3x400V~ |
Work regimes | cooling, heating, ventilation |
Structure | modular |
Condenser unit measurements (length x width x height) | 2620 x 1800 x 630 mm |
Condenser unit weight | 500 kg |
Evaporator and reheater unit measurements (length x width x height) | 2640 x 1300 x 550 mm |
Evaporator and reheater unit weight | 340 kg |
Air-conditioning device total weight | 840 kg |
Power supply voltage | 3x400V~, 3x230V~/50Hz, 24V |
Consumption power | depending on work regime |
Manner of fitting | under the car |
Cooling system: |
Compressor | helical |
Cooling power | 35 kW |
Consumption power max. | 8,3 kW |
Nominal power supply voltage | 3 x 400 V~ |
Cooling factor | R134a |
Condenser’s fans | 3 pieces at 0,9 kW |
Condenser’s fans power voltage | 3x400 V~ /50 Hz |
Condenser’s fans consumption | from 4000 to 12000 m3/h |
Evaporator and reheater module: |
Evaporator’s cooling capacity | 35 kW |
Evaporator’s core material | copper |
Heating system: |
Heating power | 10-20-30 kW |
Power supply voltage | 3x400 V~/ 50Hz |
Air consumption regulation | liquid from 1400 to 2500 m3/h |
Work conditions: |
Outside temperature | from -30 to +40°C |
Resistance to outside temperature changes | from -40 to +60°C |
Conformity with standards | UIC 553 |