Filtering devices

UFS.B2-05

Air Filter & Ventilation Equipment of UFS.BX-01 type provides an overall protection of an interior space of any personel facility against CBRN external effects of Chemical, Biological, Radiological and Nuclear contaminations as well as selected toxic industrial substances.

UFS.BX-01 Vehicle Air Filter & Ventilation Equipment of UFS.B2.01-75FW/24V,w.05 type, provides an overall protection of people and equipment inside of an interior space up to 12 m3 volume of both stationary facility as well as those designed for land transportation, including cabs (for example TATRA vehicle based special chassis), wagon chassis and container vehicle based chassis.

Air Filter & Ventilation Equipment of UFS.B2.01-75FW/24V,w.05 type is capable to operate in the following working modes: CBRN Filter & Ventilation Mode or simple Ventilation Mode only.

Operating parameters


Total Weight of filter unit50 kg
Rated Voltage (tolerated limits)27,6 VDC ±0,5 V (limits from 22 up to 30 VDC)
Rated Current (Rated power)2 A (60 W)
Implemented chemical absorberFPT-100M/P
Nominal airflow rate of filtering mode75 ± 10%
Nominal airflow rate of ventilation mode80 ± 10%
Adjusting the airflowfrom 20 m3 / h up to nominal value
Overpressure safeguard of the containerfrom 200 up to 350 Pa
Excess air pressure for overpressure safeguardmin. 500 Pa
Measurement range of the overpressure safeguardfrom 0 to 550 Pa
Registration of operation time (in hours, every minute)- of the overall working period;
- of the overall working period in the filtering & ventilation mode
Operating temperature rangefrom -30 oC up to +55°C