Air Filter & Ventilation Equipment of
UFS.BX-01 type provides an overall protection of an interior space of any personel facility against CBRN external effects of Chemical, Biological, Radiological and Nuclear contaminations as well as selected toxic industrial substances.
UFS.BX-01 Vehicle Air Filter & Ventilation Equipment of UFS.B2.01-100FW/24V,w.02 type, provides an overall protection of people and equipment inside of an interior space up to 16 m3 volume of both stationary facility as well as those designed for land transportation, including cabs, wagon chassis and container vehicle based chassis.
Air Filter & Ventilation Equipment of UFS.B2.01-100FW/24V,w.02 type is capable to operate in the following working modes: CBRN Filter & Ventilation Mode or simple Ventilation Mode only.
Operating parameters
Total Weight of filter unit | 65 kg |
Rated Voltage (tolerated limits) | 27,6 VDC ±0,5 V (limits from 22 up to 30 VDC) |
Rated Current (Rated power) | 4 A (110 W) |
Implemented chemical absorber | FPT-200M/P |
Nominal airflow rate of filtering mode | 100 ± 10% |
Nominal airflow rate of ventilation mode | 120 ± 10% |
Adjusting the airflow | from 20 m3 / h up to nominal value |
Overpressure safeguard of the container | from 200 up to 350 Pa |
Excess air pressure for overpressure safeguard | min. 500 Pa |
Measurement range of the overpressure safeguard | from 0 to 550 Pa |
Registration of operation time (in hours, every minute) | - of the overall working period; - of the overall working period in the filtering & ventilation mode |
Operating temperature range | from -30 up to + 55C°C |