Basic information: | |
Type of the equipment | UFS.B2.01 |
Type/version marking of the equipment | UFS.B2.01-100FW/24V.w.K2 |
Document marking of the equipment | UFS.B2.01-00.00.00.00.00-K2 |
Performance type | filter and ventilation/ventilation |
Operation life | 20 years |
Main overhaul | After 10 years |
Equipment’s set | - filter and ventilation module - control panel PSK.B2-K2 - user’s documentation |
Combined filter used | FPT-200M/P |
Weight of the equipment | up to 75 kg |
Power supply conditions: | |
Wiring system | direct current |
Nominal supply voltage |
27,6 VDC ±0,5 V
|
Rated power | 110 W |
Rated current | 4 A |
Control | remote via PSK.B2-K2 control panel |
Operation parameters: | |
Nominal air flow in filtering and ventilation | 100 ±10% m³/h |
Nominal air flow in ventilation | 150 ±10% m³/h |
Protected air space | up to 20 m³ |
Number of air exchanges | up to 6 per hour |
Air flow regulation | manual, via knob on the panel |
Air overpressure | 200 Pa |
Registration of work time (in hours, every min.) | - complete work - work in filtering and ventilation regime |
Work parameters: | |
Noise intensity (at a distance of 1 m) | less than 60 dB |
Range of use temperatures of the equipment | 243 - 323K (from –30 to +50°C) |
Range of storage temperatures of the equipment | 233 - 333K (from –40 to +60°C) |