Type of the equipment | UFS.BX-01 |
Type/version marking of the equipment | UFS.B2.01-100FW/24V,w.02 |
Document marking of the equipment | UFS.B2.01-00.00.00.00.00-02 |
Weight of the equipment | 65 kg |
Overall dimensions of the equipment (length x width x height) | 720 x 400 x 400 mm |
Maximum supply voltage | 27,6 VDC ±0,5 V |
Maximum supply voltage | from 22 to 30 VDC |
Rated current | 4 A |
Rated power | 110 W |
Combined filter used | FPT-200M/P |
Nominal air flow in air filtering and ventilation | 100 m³/h ±10% |
Nominal air flow in ventilation | 120 m³/h ±10% |
Adjustment of the air flow | from 20 m3/h to nominal flow rate |
Maintenance of air overpressure in the facility | from 200 to 350 Pa |
Static pressure reserve of the equipment | min. 500 Pa |
Measuring range of overpressure in the protected facility | from 0 to 550 Pa |
Control | from remote control panel |
Registration of work time (in hours, every min.) | - complete work - work in air filtering and ventilation regime |
Noise intensity (inside the facility) | below 60 dB |
Range of operation temperatures of the equipment | from -30°C to +55°C |
Range of storage temperatures of the equipment | from -40ºC to +65ºC |