Filter and ventilation devices

Portable air filtering and ventilation equipment UFP.B2.H1-200/500FW-D/230V~

Portable air filtering and ventilation equipment type UFP.BX-H1 in version UFP.B2.H1-200/500FW-D/230V~ provides protection of humans and equipment in the areas of closed facilities of an average cubature of 100 m3. The equipment provides highly effective protection of usable space of facilities against the effects of natural pollutants from the atmosphere, the use of weapons of mass destruction (WMD) and the contamination by selected industrial toxic substances.

The device can be used in two basic operating regimes:

• partial filtering - where the air provided to the premises is efficiently purified from radioactive
dusts, biological aerosols, and neutral dust (impurities present in the form of sand, dust, etc.), and
other impurities having a particle diameter> 3 mm - using high efficiency HEPA filter;

• full filtration - where aiur delivered to the premises is further purified from vapors and aerosols of
warfare agents and toxic industrial substances - using the combined filter FPT-200M / P.

In each of the above regimes of operation, the device may ensure:

• creating an overpressure in the protected usable area of the facility, to prevent the entry of contaminated air from the environment (contaminated) by possible leaks.

• creating underpressure in the usable space of the facility, to prevent the exit of the contaminated
air to the environment.
 

Technical and operation parameters

 
Type of the equipment UFP.BX-H1
Type/version marking of the equipment UFP.B2.H1-200/500FW-D/230V~
Document marking of the equipment UFP.H1-00.00.00.00.00
Total weight to 22 kg
Overall dimensions of the equipment (lenghth x width x heighth) 1450 x 720 x 910 mm
Rated current 230V~ ±10%/50Hz
Power consumption to 0,6 kW
Preliminary filter compact FC-8/50 – 2 pcs
Thorough filter highly efficient  HEPA FA14/80 - 2 pcs
Combined filter used FPT-200M/P - 1 pc
Control from built-in control panel
Use variants - creation of overpressure in the facility
- creation of underpressure in the facility
Operation regimes - full filtration
- partial filtration
Flow rate at partial filtration 500 ±10% m³/h
Flow rate at full filtration 200 ±10% m³/h
Noise intensity (at a distance of 1 m from of the equipment ) less than 70 dB
Range of use temperatures of the equipment from -30°C to +55°C
Range of storage temperatures of the equipment from -40°C to +65°C
Follow us on Facebook download our brochure