Portable air filtering and ventilation equipment type
UFP.BX-H1 in version
UFP.B2.H1-200/500FW-D/230V~ provides protection of humans and equipment in the areas of closed facilities of an average cubature of 100 m3. The equipment provides highly effective protection of usable space of facilities against the effects of natural pollutants from the atmosphere, the use of weapons of mass destruction (WMD) and the contamination by selected industrial toxic substances.
The device can be used in two basic operating regimes:
• partial filtering - where the air provided to the premises is efficiently purified from radioactive
dusts, biological aerosols, and neutral dust (impurities present in the form of sand, dust, etc.), and
other impurities having a particle diameter> 3 mm - using high efficiency HEPA filter;
• full filtration - where aiur delivered to the premises is further purified from vapors and aerosols of
warfare agents and toxic industrial substances - using the combined filter FPT-200M / P.
In each of the above regimes of operation, the device may ensure:
• creating an overpressure in the protected usable area of the facility, to prevent the entry of contaminated air from the environment (contaminated) by possible leaks.
• creating underpressure in the usable space of the facility, to prevent the exit of the contaminated
air to the environment.
Technical and operation parameters
Type of the equipment |
UFP.BX-H1 |
Type/version marking of the equipment |
UFP.B2.H1-200/500FW-D/230V~ |
Document marking of the equipment |
UFP.H1-00.00.00.00.00 |
Total weight |
to 22 kg |
Overall dimensions of the equipment (lenghth x width x heighth) |
1450 x 720 x 910 mm |
Rated current |
230V~ ±10%/50Hz |
Power consumption |
to 0,6 kW |
Preliminary filter |
compact FC-8/50 – 2 pcs |
Thorough filter |
highly efficient HEPA FA14/80 - 2 pcs |
Combined filter used |
FPT-200M/P - 1 pc |
Control |
from built-in control panel |
Use variants |
- creation of overpressure in the facility
- creation of underpressure in the facility |
Operation regimes |
- full filtration
- partial filtration |
Flow rate at partial filtration |
500 ±10% m³/h |
Flow rate at full filtration |
200 ±10% m³/h |
Noise intensity (at a distance of 1 m from of the equipment ) |
less than 70 dB |
Range of use temperatures of the equipment |
from -30°C to +55°C |
Range of storage temperatures of the equipment |
from -40°C to +65°C |